ebusd and vailant ecotech plus plus controller

 ebusctl

 

localhost: find -c bai
bai AccessoriesOne = no data stored
bai AccessoriesTwo = no data stored
bai ACRoomthermostat = no data stored
bai AntiCondensValue = no data stored
bai averageIgnitiontime = no data stored
bai BlockTimeHcMax = no data stored
bai BoilerType = no data stored
bai ChangesDSN = no data stored
bai CirPump = no data stored
bai CodingResistor = no data stored
bai CounterStartattempts1 = no data stored
bai CounterStartattempts2 = no data stored
bai CounterStartAttempts3 = no data stored
bai CounterStartAttempts4 = no data stored
bai currenterror = no data stored
bai DateTime = no data stored
bai dcfState = no data stored
bai DCFTimeDate = no data stored
bai DCRoomthermostat = on
bai DeactivationsIFC = no data stored
bai DeactivationsTemplimiter = no data stored
bai DeltaFlowReturnMax = no data stored
bai DisplayMode = no data stored
bai DSN = no data stored
bai DSNOffset = no data stored
bai DSNStart = no data stored
bai EBusHeatcontrol = no data stored
bai EbusSourceOn = no data stored
bai EbusVoltage = no data stored
bai errorhistory = no data stored
bai ExternalFaultmessage = no data stored
bai externalHwcSwitch = no data stored
bai ExternGasvalve = no data stored
bai ExtFlowTempDesiredMin = no data stored
bai ExtStorageModulCon = no data stored
bai extWP = no data stored
bai FanHours = no data stored
bai FanMaxSpeedOperation = no data stored
bai FanMinSpeedOperation = no data stored
bai FanPWMSum = no data stored
bai FanPWMTest = no data stored
bai FanSpeed = no data stored
bai FanSpeedOffsetMax = no data stored
bai FanSpeedOffsetMin = no data stored
bai FanStarts = no data stored
bai Flame = no data stored
bai FlameSensingASIC = no data stored
bai FloorHeatingContact = no data stored
bai FlowsetHcMax = no data stored
bai FlowsetHwcMax = no data stored
bai FlowTemp = 24.69;ok
bai FlowTempDesired = 15.00
bai FlowTempMax = no data stored
bai Fluegasvalve = no data stored
bai FluegasvalveOpen = no data stored
bai Gasvalve3UC = no data stored
bai GasvalveASICFeedback = no data stored
bai GasvalveUC = no data stored
bai GasvalveUCFeedback = no data stored
bai HcHours = no data stored
bai HcPumpMode = no data stored
bai HcPumpStarts = no data stored
bai HcStarts = no data stored
bai HcUnderHundredStarts = no data stored
bai HeatingSwitch = no data stored
bai HoursTillService = no data stored
bai HwcDemand = no data stored
bai HwcHours = no data stored
bai HwcImpellorSwitch = no data stored
bai HwcPostrunTime = no data stored
bai HwcStarts = no data stored
bai HwcSwitch = no data stored
bai HwcTemp = 116.06;circuit
bai HwcTempDesired =  (ERR: invalid position for 3108b509030dea03 / 00)
bai HwcTempMax = no data stored
bai HwcTypes = no data stored
bai HwcUnderHundredStarts = no data stored
bai HwcWaterflow = no data stored
bai HwcWaterflowMax = no data stored
bai Ignitor = no data stored
bai InitialisationEEPROM = no data stored
bai IonisationVoltageLevel = no data stored
bai maintenancedata_HwcTempMax = no data stored
bai maxIgnitiontime = no data stored
bai minIgnitiontime = no data stored
bai ModulationTempDesired = no data stored
bai OptionalRelais = no data stored
bai OutdoorstempSensor = no data stored
bai OverflowCounter = no data stored
bai ParamToken = no data stored
bai PartloadHcKW = no data stored
bai PartloadHwcKW = no data stored
bai PartnumberBox = no data stored
bai PositionValveSet = no data stored
bai PowerValue = no data stored
bai PrAPSCounter = no data stored
bai PrAPSSum = no data stored
bai PrEnergyCountHc1 = no data stored
bai PrEnergyCountHc2 = no data stored
bai PrEnergyCountHc3 = no data stored
bai PrEnergyCountHwc1 = no data stored
bai PrEnergyCountHwc2 = no data stored
bai PrEnergyCountHwc3 = no data stored
bai PrEnergySumHc1 = no data stored
bai PrEnergySumHc2 = no data stored
bai PrEnergySumHc3 = no data stored
bai PrEnergySumHwc1 = no data stored
bai PrEnergySumHwc2 = no data stored
bai PrEnergySumHwc3 = no data stored
bai ProductionByte = no data stored
bai PrVortexFlowSensorValue = no data stored
bai PumpHours = no data stored
bai PumpHwcFlowNumber = no data stored
bai PumpHwcFlowSum = no data stored
bai PumpPower = no data stored
bai PumpPowerDesired = no data stored
bai RemainingBoilerblocktime = no data stored
bai ReturnRegulation = no data stored
bai ReturnTemp = no data stored
bai ReturnTempExternal = no data stored
bai ReturnTempMax = no data stored
bai SerialNumber = no data stored
bai SetFactoryValues = no data stored
bai SetMode = auto;15.0;-;-;1;0;0;0;0;0
bai SHEMaxDeltaHwcFlow = no data stored
bai SHEMaxFlowTemp = no data stored
bai SolPostHeat = no data stored
bai SpecialAdj = no data stored
bai Statenumber = no data stored
bai Status01 = 24.5;25.0;-;-;59.0;off
bai Status02 = auto;60;75.0;70;70.0
bai Status16 = no data stored
bai Status = no data stored
bai StatusCirPump = no data stored
bai Storageloadpump = no data stored
bai StorageLoadPumpHours = no data stored
bai StorageloadPumpStarts = no data stored
bai StorageLoadTimeMax = no data stored
bai StoragereleaseClock = no data stored
bai StorageTemp = 58.94;ok
bai StorageTempDesired = 36.00
bai StorageTempMax = no data stored
bai TargetFanSpeed = no data stored
bai TargetFanSpeedOutput = no data stored
bai TempDiffBlock = no data stored
bai TempDiffFailure = no data stored
bai TempGradientFailure = no data stored
bai Templimiter = no data stored
bai TemplimiterWithNTC = no data stored
bai TempMaxDiffExtTFT = no data stored
bai Testbyte = no data stored
bai TimerInputHc = no data stored
bai ValveMode = no data stored
bai ValveStarts = no data stored
bai VolatileLockout = no data stored
bai VolatileLockoutIFCGV = no data stored
bai WarmstartDemand = no data stored
bai WarmstartOffset = no data stored
bai WaterHcFlowMax = no data stored
bai WaterPressure = 1.018;ok
bai WaterpressureBranchControlOff = no data stored
bai WaterpressureMeasureCounter = no data stored
bai WaterpressureVariantSum = no data stored
bai WP = no data stored
bai WPPostrunTime = no data stored
bai WPSecondStage = no data stored

localhost: i
version: ebusd 21.2.v21.2
update check: OK
signal: acquired
symbol rate: 23
max symbol rate: 73
min arbitration micros: 7
max arbitration micros: 54
min symbol latency: 4
max symbol latency: 5
reconnects: 0
masters: 3
messages: 219
conditional: 3
poll: 0
update: 10
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0204;HW=9602", loaded "vaillant/bai.0010021961.inc" ([PROD='0010021963']), "vaillant/08.bai.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=05000;SW=0113;HW=9601"
address 31: master #8, ebusd
address 36: slave #8, ebusd

Коментарі

  1. if turned water heatin off and on got messages
    listen
    bai SetMode = auto;15.0;-;-;1;0;1;0;0;0
    bai SetMode = auto;15.0;-;-;1;0;0;0;0;0

    ВідповістиВидалити

Дописати коментар

Популярні дописи з цього блогу

Home assistant - modbus - HHC-N8I8OP

Thanks to https://www.cncwiki.org/index.php?title=HHC-N8I8OP  I managed to connect this buggy module to home assistant using modbus integration: It is important to have verify delay big to not break logic.  modbus:   - type: tcp     host: 192.168.222.222     port: 5000     name: "modbus1"     switches:       - name: "hhc_r8"         address: 16         write_type: coil         verify:           delay: 36       - name: "hhc_r7"         address: 17         write_type: coil         verify:           delay: 37       - name: "hhc_r6"         address: 18         write_type: coil         verify:           delay: 39       - name: "hhc_r5"         address: 19         write_type: coil         verify:           delay: 48       - name: "hhc_r4"         address: 20         write_type: coil         verify:           delay: 28       - name: "hhc_r3"         address: 21         write_type: coil         verify:           delay: 33

How to symbolicate crash logs in XCode organizer

If you have application distributed through Apple appstore or Testflight you should be able to get automatic crash reports by opening XCode/Window/Organizer menu, then select app and go to Crashes tab. If crashes are not symbolicated you can symbolicate them manually by: 1. In organizer, call for context menu by pressing on crash log call stack section 2. Select "show in finder ..." menu item 3. Navigate up to ~/Library/Developer/Xcode/Products/ [app bundle id]/ [app version]/Crashes/Appstore/ 4. Copy debug symbols there: 5. Go back to Organizer and select "Resymbolicate" context menu item on call stack area. Now you should be able to see symbolicated log. Works for me on XCode 10 and Testflight.