ebusd and vailant ecotech plus plus controller

 ebusctl

 

localhost: find -c bai
bai AccessoriesOne = no data stored
bai AccessoriesTwo = no data stored
bai ACRoomthermostat = no data stored
bai AntiCondensValue = no data stored
bai averageIgnitiontime = no data stored
bai BlockTimeHcMax = no data stored
bai BoilerType = no data stored
bai ChangesDSN = no data stored
bai CirPump = no data stored
bai CodingResistor = no data stored
bai CounterStartattempts1 = no data stored
bai CounterStartattempts2 = no data stored
bai CounterStartAttempts3 = no data stored
bai CounterStartAttempts4 = no data stored
bai currenterror = no data stored
bai DateTime = no data stored
bai dcfState = no data stored
bai DCFTimeDate = no data stored
bai DCRoomthermostat = on
bai DeactivationsIFC = no data stored
bai DeactivationsTemplimiter = no data stored
bai DeltaFlowReturnMax = no data stored
bai DisplayMode = no data stored
bai DSN = no data stored
bai DSNOffset = no data stored
bai DSNStart = no data stored
bai EBusHeatcontrol = no data stored
bai EbusSourceOn = no data stored
bai EbusVoltage = no data stored
bai errorhistory = no data stored
bai ExternalFaultmessage = no data stored
bai externalHwcSwitch = no data stored
bai ExternGasvalve = no data stored
bai ExtFlowTempDesiredMin = no data stored
bai ExtStorageModulCon = no data stored
bai extWP = no data stored
bai FanHours = no data stored
bai FanMaxSpeedOperation = no data stored
bai FanMinSpeedOperation = no data stored
bai FanPWMSum = no data stored
bai FanPWMTest = no data stored
bai FanSpeed = no data stored
bai FanSpeedOffsetMax = no data stored
bai FanSpeedOffsetMin = no data stored
bai FanStarts = no data stored
bai Flame = no data stored
bai FlameSensingASIC = no data stored
bai FloorHeatingContact = no data stored
bai FlowsetHcMax = no data stored
bai FlowsetHwcMax = no data stored
bai FlowTemp = 24.69;ok
bai FlowTempDesired = 15.00
bai FlowTempMax = no data stored
bai Fluegasvalve = no data stored
bai FluegasvalveOpen = no data stored
bai Gasvalve3UC = no data stored
bai GasvalveASICFeedback = no data stored
bai GasvalveUC = no data stored
bai GasvalveUCFeedback = no data stored
bai HcHours = no data stored
bai HcPumpMode = no data stored
bai HcPumpStarts = no data stored
bai HcStarts = no data stored
bai HcUnderHundredStarts = no data stored
bai HeatingSwitch = no data stored
bai HoursTillService = no data stored
bai HwcDemand = no data stored
bai HwcHours = no data stored
bai HwcImpellorSwitch = no data stored
bai HwcPostrunTime = no data stored
bai HwcStarts = no data stored
bai HwcSwitch = no data stored
bai HwcTemp = 116.06;circuit
bai HwcTempDesired =  (ERR: invalid position for 3108b509030dea03 / 00)
bai HwcTempMax = no data stored
bai HwcTypes = no data stored
bai HwcUnderHundredStarts = no data stored
bai HwcWaterflow = no data stored
bai HwcWaterflowMax = no data stored
bai Ignitor = no data stored
bai InitialisationEEPROM = no data stored
bai IonisationVoltageLevel = no data stored
bai maintenancedata_HwcTempMax = no data stored
bai maxIgnitiontime = no data stored
bai minIgnitiontime = no data stored
bai ModulationTempDesired = no data stored
bai OptionalRelais = no data stored
bai OutdoorstempSensor = no data stored
bai OverflowCounter = no data stored
bai ParamToken = no data stored
bai PartloadHcKW = no data stored
bai PartloadHwcKW = no data stored
bai PartnumberBox = no data stored
bai PositionValveSet = no data stored
bai PowerValue = no data stored
bai PrAPSCounter = no data stored
bai PrAPSSum = no data stored
bai PrEnergyCountHc1 = no data stored
bai PrEnergyCountHc2 = no data stored
bai PrEnergyCountHc3 = no data stored
bai PrEnergyCountHwc1 = no data stored
bai PrEnergyCountHwc2 = no data stored
bai PrEnergyCountHwc3 = no data stored
bai PrEnergySumHc1 = no data stored
bai PrEnergySumHc2 = no data stored
bai PrEnergySumHc3 = no data stored
bai PrEnergySumHwc1 = no data stored
bai PrEnergySumHwc2 = no data stored
bai PrEnergySumHwc3 = no data stored
bai ProductionByte = no data stored
bai PrVortexFlowSensorValue = no data stored
bai PumpHours = no data stored
bai PumpHwcFlowNumber = no data stored
bai PumpHwcFlowSum = no data stored
bai PumpPower = no data stored
bai PumpPowerDesired = no data stored
bai RemainingBoilerblocktime = no data stored
bai ReturnRegulation = no data stored
bai ReturnTemp = no data stored
bai ReturnTempExternal = no data stored
bai ReturnTempMax = no data stored
bai SerialNumber = no data stored
bai SetFactoryValues = no data stored
bai SetMode = auto;15.0;-;-;1;0;0;0;0;0
bai SHEMaxDeltaHwcFlow = no data stored
bai SHEMaxFlowTemp = no data stored
bai SolPostHeat = no data stored
bai SpecialAdj = no data stored
bai Statenumber = no data stored
bai Status01 = 24.5;25.0;-;-;59.0;off
bai Status02 = auto;60;75.0;70;70.0
bai Status16 = no data stored
bai Status = no data stored
bai StatusCirPump = no data stored
bai Storageloadpump = no data stored
bai StorageLoadPumpHours = no data stored
bai StorageloadPumpStarts = no data stored
bai StorageLoadTimeMax = no data stored
bai StoragereleaseClock = no data stored
bai StorageTemp = 58.94;ok
bai StorageTempDesired = 36.00
bai StorageTempMax = no data stored
bai TargetFanSpeed = no data stored
bai TargetFanSpeedOutput = no data stored
bai TempDiffBlock = no data stored
bai TempDiffFailure = no data stored
bai TempGradientFailure = no data stored
bai Templimiter = no data stored
bai TemplimiterWithNTC = no data stored
bai TempMaxDiffExtTFT = no data stored
bai Testbyte = no data stored
bai TimerInputHc = no data stored
bai ValveMode = no data stored
bai ValveStarts = no data stored
bai VolatileLockout = no data stored
bai VolatileLockoutIFCGV = no data stored
bai WarmstartDemand = no data stored
bai WarmstartOffset = no data stored
bai WaterHcFlowMax = no data stored
bai WaterPressure = 1.018;ok
bai WaterpressureBranchControlOff = no data stored
bai WaterpressureMeasureCounter = no data stored
bai WaterpressureVariantSum = no data stored
bai WP = no data stored
bai WPPostrunTime = no data stored
bai WPSecondStage = no data stored

localhost: i
version: ebusd 21.2.v21.2
update check: OK
signal: acquired
symbol rate: 23
max symbol rate: 73
min arbitration micros: 7
max arbitration micros: 54
min symbol latency: 4
max symbol latency: 5
reconnects: 0
masters: 3
messages: 219
conditional: 3
poll: 0
update: 10
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0204;HW=9602", loaded "vaillant/bai.0010021961.inc" ([PROD='0010021963']), "vaillant/08.bai.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=05000;SW=0113;HW=9601"
address 31: master #8, ebusd
address 36: slave #8, ebusd

Коментарі

  1. if turned water heatin off and on got messages
    listen
    bai SetMode = auto;15.0;-;-;1;0;1;0;0;0
    bai SetMode = auto;15.0;-;-;1;0;0;0;0;0

    ВідповістиВидалити

Дописати коментар

Популярні дописи з цього блогу

How to symbolicate crash logs in XCode organizer

If you have application distributed through Apple appstore or Testflight you should be able to get automatic crash reports by opening XCode/Window/Organizer menu, then select app and go to Crashes tab. If crashes are not symbolicated you can symbolicate them manually by: 1. In organizer, call for context menu by pressing on crash log call stack section 2. Select "show in finder ..." menu item 3. Navigate up to ~/Library/Developer/Xcode/Products/ [app bundle id]/ [app version]/Crashes/Appstore/ 4. Copy debug symbols there: 5. Go back to Organizer and select "Resymbolicate" context menu item on call stack area. Now you should be able to see symbolicated log. Works for me on XCode 10 and Testflight.

Home assistant - modbus - HHC-N8I8OP

Thanks to https://www.cncwiki.org/index.php?title=HHC-N8I8OP  I managed to connect this buggy module to home assistant using modbus integration: It is important to have verify delay big to not break logic.  modbus:   - type: tcp     host: 192.168.222.222     port: 5000     name: "modbus1"     switches:       - name: "hhc_r8"         address: 16         write_type: coil         verify:           delay: 36       - name: "hhc_r7"         address: 17         write_type: coil         verify:           delay: 37       - name: "hhc_r6"   ...