HomeAssistant gadinan camera rest commands pan and tilt

 Add following to restcommand.yaml and include in config.yaml:

 

# rest_command:
ptz_control_right:
url: "http://192.168.16.253/PSIA/YG/PTZCtrl/channels/0/continuous?pan=1&tilt=0"
method: PUT
headers:
Cookie: "cur_UserInfo=admin%3A123456; cur_userName=admin;"
Content-Length: "0"
ptz_control_left:
url: "http://192.168.16.253/PSIA/YG/PTZCtrl/channels/0/continuous?pan=-1&tilt=0"
method: PUT
headers:
Cookie: "cur_UserInfo=admin%3A123456; cur_userName=admin;"
Content-Length: "0"
ptz_control_stop:
url: "http://192.168.16.253/PSIA/YG/PTZCtrl/channels/0/continuous?pan=0&tilt=0"
method: PUT
headers:
Cookie: "cur_UserInfo=admin%3A123456; cur_userName=admin;"
Content-Length: "0"
ptz_control_up:
url: "http://192.168.16.253/PSIA/YG/PTZCtrl/channels/0/continuous?pan=0&tilt=1"
method: PUT
headers:
Cookie: "cur_UserInfo=admin%3A123456; cur_userName=admin;"
Content-Length: "0"
ptz_control_down:
url: "http://192.168.16.253/PSIA/YG/PTZCtrl/channels/0/continuous?pan=0&tilt=-1"
method: PUT
headers:
Cookie: "cur_UserInfo=admin%3A123456; cur_userName=admin;"
Content-Length: "0"


 Then it will be possible to add buttons that triggers corresponding actions.

 

Коментарі

Популярні дописи з цього блогу

ebusd and vailant ecotech plus plus controller

 ebusctl   localhost: find -c bai bai AccessoriesOne = no data stored bai AccessoriesTwo = no data stored bai ACRoomthermostat = no data stored bai AntiCondensValue = no data stored bai averageIgnitiontime = no data stored bai BlockTimeHcMax = no data stored bai BoilerType = no data stored bai ChangesDSN = no data stored bai CirPump = no data stored bai CodingResistor = no data stored bai CounterStartattempts1 = no data stored bai CounterStartattempts2 = no data stored bai CounterStartAttempts3 = no data stored bai CounterStartAttempts4 = no data stored bai currenterror = no data stored bai DateTime = no data stored bai dcfState = no data stored bai DCFTimeDate = no data stored bai DCRoomthermostat = on bai DeactivationsIFC = no data stored bai DeactivationsTemplimiter = no data stored bai DeltaFlowReturnMax = no data stored bai DisplayMode = no data stored bai DSN = no data stored bai DSNOffset = no data stored bai DSNStart = no data stored bai EBusHeatcontrol = no data store...

Home assistant - modbus - HHC-N8I8OP

Thanks to https://www.cncwiki.org/index.php?title=HHC-N8I8OP  I managed to connect this buggy module to home assistant using modbus integration: It is important to have verify delay big to not break logic.  modbus:   - type: tcp     host: 192.168.222.222     port: 5000     name: "modbus1"     switches:       - name: "hhc_r8"         address: 16         write_type: coil         verify:           delay: 36       - name: "hhc_r7"         address: 17         write_type: coil         verify:           delay: 37       - name: "hhc_r6"   ...

How to symbolicate crash logs in XCode organizer

If you have application distributed through Apple appstore or Testflight you should be able to get automatic crash reports by opening XCode/Window/Organizer menu, then select app and go to Crashes tab. If crashes are not symbolicated you can symbolicate them manually by: 1. In organizer, call for context menu by pressing on crash log call stack section 2. Select "show in finder ..." menu item 3. Navigate up to ~/Library/Developer/Xcode/Products/ [app bundle id]/ [app version]/Crashes/Appstore/ 4. Copy debug symbols there: 5. Go back to Organizer and select "Resymbolicate" context menu item on call stack area. Now you should be able to see symbolicated log. Works for me on XCode 10 and Testflight.